Item successfully added to your cart view cart

Contec Patient Monitor CMS9000 & Nibp/Spo2/Temp/ECG

Contec Patient Monitor CMS9000 & Nibp/Spo2/Temp/ECG

Regular price

R 20,046.99

Prices Include VAT

More about the Contec Patient Monitor CMS9000 & Nibp/Spo2/Temp/ECG

This device can monitor such parameters as ECG, RESP, SpO2, PR, NIBP and dual-channel TEMP, etc. It integrates parameter measurement module, display and recorder in one device to form a compact and portable equipment. At the same time, its built-in replaceable battery provides convenience for patient moving.

Functions:
  • Standard parameters: ECG, RESP, SpO2, PR, NIBP, dual-channel TEMP
  • ECG Heart rate(HR)
  • ECG waveform
  • Arrhythmia and ST-segment analysis
  • RESP Respiration rate(RR)
  • Respiration waveform
  • 3)SpO2 Pulse oxygen saturation(SpO2)
  • Plethysmogram(PLETH) waveform
  • Pulse rate(PR)
  • Bar graph
  • NIBP Systolic pressure(SYS), Diastolic pressure(DIA), Mean pressure(MEAN)
  • TEMP T1, T2, TD
  • It has abundant functions, such as audible and visual alarm, trend data storage and output, NIBP measurement, alarm event marking and drug concentration calculation, etc.

Features:
  • 12.1'' TFT color LCD, multi-language interface:Simplified Chinese, Traditional Chinese, English, French, German, Turkish, Spanish(Europe), Spanish(Mexico),Portuguese, Italian, Dutch, Romanian, Russian, Kazakh, Polish, Czech,Bulgarian, Ukraine”
  • Fanless design, quiet, energy-saving and clean, which reduces the possibility of cross-infection.
  • All-round monitor for adult, pediatric and neonate.
  • With standard interface, OxyCRG, trend chard, big character interface and view bed, convenient to observe.
  • Waveform, parameter color and location can be set optionally.
  • Operation mode: keys and buttons.
  • Display up to 8-channel waveform on one screen.
  • Display 7-lead ECG waveform on one screen, and with ECG step function.
  • Adopt digital SpO2 technology, anti-motion and anti-ambient light interference, and measurement can be performed under the circumstance of weak filling.
  • HRV analysis function.
  • NIBP measurement mode: Manual/AUTO/Continuous, storage for 4800-group NIBP data.
  • Review for 71 alarm events of all parameters and 60 arrhythmia alarm events.
  • Drug concentration calculation and titration table functions.
  • Print trend table data with one-key.
  • Connect to Central Monitoring System by 3G, WiFi or wired mode.
  • AC/DC, built-in rechargeable lithium battery achieve uninterrupted monitoring.
  • Anti-high frequency surgical unit, defibrillation-proof(special leads are necessary).

Performance:
ECG
  • Lead mode: 3-lead or 5-lead
  • Lead selection: I, II, III, aVR, aVL, aVF, V
  • Waveform: 5-lead, 2-channel
  • 3-lead, 1-channel
  • Gain: 2.5mm/mV, 5.0mm/mV, 10mm/mV, 20mm/mV, 40mm/mV
  • Scan speed: 12.5mm/s, 25 mm/s, 50 mm/s
HR:
  • Measurement and alarm range: 15~300bpm
  • Accuracy: ±1% or ±1bpm, whichever is greater
  • Alarm accuracy: ± 2 bpm
  • Resolution: 1 bpm
  • ST-segment monitoring:
  • Measurement and alarm range: -2.0mV~+2.0mV
  • Accuracy: -0.8mv~+0.8mv ±0.04mv or ±10%, whichever is greater
  • Other range: unspecified
  • Arrhythmia analysis: ASYSTOLE, VFIB/VTAC, COUPLET, BIGEMINY, TRIGEMINY, R ON T, VT>2, PVC, TACHY, BRADY, MISSED BEATS, PNP, PNC
  • Pacemaker: yes
RESPIRATION
  • Method: R-F(RA-LL) Impedance
  • Respiration rate:
  • Measurement and alarm range: 0~150rpm
  • Resolution: 1 rpm
  • Measurement accuracy: ±2 rpm
  • Alarm accuracy: ±3 rpm
  • Apnea alarm: 10~40s
  • Scan speed: 6.25 mm/s, 12.5 mm/s, 25 mm/s
NIBP
  • Method: Oscillometry
  • Mode: Manual/AUTO/Continuous
  • Measurement interval in AUTO mode: 1/2/3/4/5/10/15/30/60/90/120/240/480/960 minutes
  • Measurement period in Continuous mode: 5 minutes
  • Measurement and alarm range: 10 ~ 270 mmHg
  • Resolution: 1 mmHg
  • Cuff pressure accuracy: ±3 mmHg
  • Measurement accuracy:
  • Maximal mean deviation: ±5 mmHg
  • Maximal standard deviation: 8mmHg
  • Over-pressure protection:
  • Adult mode: 297±3 mmHg
  • Pediatric mode: 240±3 mmHg
  • Neonatal mode: 147±3 mmHg
SpO2
  • Measurement and alarm range: 0 ~ 100%
  • Resolution: 1%
  • Measurement accuracy: 70%~100%: ±2%;
  • 0%~69%: unspecified
PR
  • Measurement and alarm range: 25 ~ 250 bpm
  • Measurement accuracy: ±2 bpm or ±2%, whichever is greater
TEMP
  • Channel: dual-channel
  • Measurement and alarm range: 0 ~ 50℃
  • Resolution: 0.1 ℃
  • Accuracy: ±0.1 ℃
EtCO2
  • Method: Sidestream or Mainstream
  • Measurement range for CO2: 0~150mmHg
  • Resolution for CO2:
  • 0 ~ 69 mmHg: 0.1 mmHg
  • 70 ~ 150 mmHg: 0.25 mmHg
  • Accuracy for CO2:
  • 0 ~ 40 mmHg: ±2 mmHg
  • 41 ~ 70 mmHg: ±5%
  • 71 ~ 100 mmHg: ±8%
  • 101 ~ 150 mmHg: ±10%
  • AwRR range: 2~150 rpm
  • AwRR accuracy: ±1 rpm
  • Apnea alarm: yes
IBP
  • Channel: dual-channel
  • Label: ART, PA, CVP, RAP, LAP, ICP, P1, P2
  • Measurement and alarm range: -10~300 mmHg
  • Resolution: 1 mmHg
  • Accuracy: ±2% or 1mmHg, whichever is greater
  • Power supply:AC 100-240V, 50/60Hz
  • Safety classification: Class I, type CF defibrillation-proof applied part

Accessories:
  • Adult fingertip SpO2 probe (5-pin)
  • Adult NIBP cuff
  • NIBP extension tube
  • ECG lead cable
  • ECG electrode
  • Temperature probe
  • Power cord
  • User Manual(GB only)on request for other Language

Physical characteristic:
  • Dimension: 319 mm(L) × 161 mm(W) × 269 mm(H)
  • Weight: <3.0 kg(excluding accessories)

Lead time:

Our lead times are 5-7 working days excluding weekends, public holiday’s & shipping time with our courier.

Lead times on out of stock or special-order items 6-8 weeks / 8-10 weeks

PLEASE NOTE DUE TO UNFORSEEN ROAD OR AIR FREIGHT DELAYS PARECELS CAN BE DELAYED BY A FEW DAYS. 

*Please note pictures are mainly for illustration purposes, actual product and size may vary slightly*